Hantek DSO2D10

Hantek DSO2D10 Digital Storage Oscilloscope User Manual

Model: DSO2D10 | Brand: Hantek

1. Hyrje

This manual provides essential information for the safe and effective operation of your Hantek DSO2D10 Digital Storage Oscilloscope. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage.

Hantek DSO2D10 Digital Storage Oscilloscope front view

Figure 1: Hantek DSO2D10 Digital Storage Oscilloscope

2. Informacion mbi sigurinë

Always observe the following safety precautions to prevent injury and avoid damage to the instrument or any products connected to it.

  • Burimi i energjisë: Use only the power cord specified for this instrument. Ensure the power supply voltage është brenda intervalit të specifikuar.
  • Tokëzimi: The instrument must be properly grounded. Do not defeat the grounding conductor of the power cord.
  • Siguria e sondës: Ensure probes are correctly connected and rated for the voltage being measured. Do not touch exposed connections or components when power is applied.
  • Mjedisi: Operate the instrument in a well-ventilated area. Do not operate in wet or damp conditions, or in explosive atmospheres.
  • Mirëmbajtja: Refer all servicing to qualified service personnel. Do not attempt to service the instrument yourself.

3. Produkti i Mbaruarview

3.1 Karakteristikat kryesore

  • Features 2 independent channels with dedicated knob control.
  • Gjerësia e brezit analog 100 MHz dhe 1 GSa/s në kohë realeampnorma e këmbimit.
  • Equipped with a 7-inch TFT LCD screen, 800x480 pixels, displaying 16 million colors (24-bit true color).
  • Integrated 25 MHz signal generator, supporting arbitrary waveform burst output and modulation waveform output.
  • Capable of saving parameters, waveforms, reference waveforms, CSV, and images.
  • Includes 5-digit digital voltmeter and 6-digit hardware frequency counter functions.
  • Large storage depth of 8Mpts to minimize waveform distortion and restore real waveforms.

3.2 Përshkrimi fizik

The Hantek DSO2D10 is designed for portability and ease of use. Below are various views të pajisjes.

Front, Rear, and Side views of the Hantek DSO2D10 Oscilloscope

Figure 2: Front, Rear, and Side Views

The device measures approximately 318mm in width, 140mm in depth, and 150mm in height, making it compact for various applications.

Dimensions of the Hantek DSO2D10 Oscilloscope

Figure 3: Oscilloscope Dimensions

3.3 Identifikimi i Komponentit

Familiarize yourself with the main components and controls of the oscilloscope.

Labeled components of the Hantek DSO2D10 Oscilloscope

Figura 4: Paraqitja e panelit të përparmë

  • Ekrani LCD: 7-inch TFT screen for waveform display and menu navigation.
  • Option Buttons (F1-F6): Context-sensitive function buttons.
  • Executive Control Buttons: Buttons for various functions like Menu, Utility, Cursor, Display, Acquire, etc.
  • Kontrollet vertikale: VOLTS/DIV knobs and POSITION knobs for Channel 1 (CH1) and Channel 2 (CH2).
  • Kontrollet horizontale: SEC/DIV knob and POSITION knob for time base adjustment.
  • Niveli i aktivizimit: Knob to adjust the trigger level.
  • Analog Channel Input (CH1, CH2): BNC connectors for probe input.
  • External Trigger Input (EXT TRIG/GEN OUT): BNC connector for external trigger or signal generator output.
  • Ndërfaqja USB: For data transfer and firmware updates.
  • Ndërprerësi i energjisë: Për të ndezur ose fikur pajisjen.

4. Konfigurimi

4.1 Shpaketimi dhe inspektimi

Carefully remove the oscilloscope from its packaging. Inspect the device for any signs of damage during transit. Retain the packaging for future storage or shipping.

4.2 Lidhja e energjisë

  1. Sigurohuni që çelësi i rrymës të jetë në pozicionin OFF.
  2. Lidhni kabllon e energjisë të dhënë me hyrjen e energjisë në panelin e pasmë të osciloskopit.
  3. Lidhni anën tjetër të kabllit të energjisë në një prizë të tokëzuar të energjisë AC.

4.3 Kompensimi i sondës

Before taking measurements, it is crucial to compensate your oscilloscope probes to ensure accurate readings. This process adjusts the probe's capacitance to match the oscilloscope's input impedance.

  1. Connect a probe to Channel 1 (CH1) input.
  2. Connect the probe tip to the probe compensation output (usually a square wave test point on the front panel) and the ground clip to the ground terminal.
  3. Turn on the oscilloscope. A square wave should appear on the screen.
  4. Using a small screwdriver, adjust the compensation screw on the probe body until the square wave displayed on the screen has flat tops and bottoms with no overshoot or undershoot.
  5. Repeat for other probes and channels as necessary.

5. Udhëzimet e funksionimit

5.1 Ndezja/Fikja

Press the Power Switch located on the front panel to turn the oscilloscope ON or OFF.

5.2 Shfaqja bazë e formës së valës

  1. Connect a signal source to CH1 using a compensated probe.
  2. Rregulloni VOLTS/DIV knob for CH1 to set the vertical scale.
  3. Rregulloni SEC/DIV knob to set the horizontal (time) scale.
  4. Rregulloni POZICIONI knobs (vertical and horizontal) to center the waveform on the screen.
  5. Rregulloni NIVELI I SHKAKTIMIT knob until a stable waveform is displayed.

5.3 Matje Automatike

The DSO2D10 supports 32 types of automatic measurements, simplifying waveform analysis.

Screenshot showing 32 automatic measurements on Hantek DSO2D10

Figure 5: Automatic Measurement Display

To access automatic measurements, press the MASA button and use the option buttons (F1-F6) to select desired parameters such as Frequency, Period, Peak-to-Peak Voltage, RMS Voltage, etc. The results will be displayed on the screen.

5.4 Signal Generator Function

The built-in 25 MHz signal generator can output various waveforms. Connect the EXT TRIG/GEN OUT BNC connector to your circuit under test.

  1. Shtypni vrull button or navigate through the menu to access the signal generator settings.
  2. Select the desired waveform type (e.g., sine, square, arbitrary).
  3. Adjust parameters such as frequency, amplitude, and duty cycle using the corresponding controls or menu options.

5.5 Ruajtja dhe Rikthimi i të Dhënave

The oscilloscope features an 8Mpts storage depth, allowing for detailed waveform capture and analysis. You can save and recall various data types.

Screenshot illustrating 8Mpts storage depth on Hantek DSO2D10

Figure 6: Waveform Storage Depth

To save data, press the SAVE/TO USB button and follow the on-screen prompts to save parameters, waveforms, or screenshots to internal memory or a connected USB drive.

5.6 Digital Voltmeter and Frequency Counter

The DSO2D10 includes integrated 5-digit digital voltmeter (DVM) and 6-digit hardware frequency counter functions for precise measurements.

Screenshot showing Dual DVM and Frequency Meter functions on Hantek DSO2D10

Figure 7: Dual DVM and Frequency Counter

These functions can be accessed via the PËRDORIMI or MASA menus, providing real-time digital readouts of voltage dhe frekuencës.

6. Mirëmbajtja

6.1 Pastrimi

Clean the instrument regularly with a soft, damp cloth. Do not use abrasive cleaners or solvents that could damage the casing or screen. Ensure the device is powered off and unplugged before cleaning.

6.2 Kalibrimi

The oscilloscope is factory calibrated. For continued accuracy, periodic calibration by qualified service personnel is recommended, especially after significant temperature changes or prolonged use.

6.3 Ruajtja

When not in use, store the oscilloscope in a dry, dust-free environment, away from direct sunlight and extreme temperatures. Use the original packaging for long-term storage if available.

7. Troubleshooting

This section addresses common issues you might encounter with the Hantek DSO2D10.

ProblemShkaku i mundshëmZgjidhje
Asnjë ekran pas ndezjes.Power cable not connected, power outlet faulty, device fault.Check power cable connection. Test power outlet. If problem persists, contact support.
Unstable or distorted waveform.Incorrect trigger settings, uncompensated probe, signal too weak/strong.Adjust trigger level. Perform probe compensation (see Section 4.3). Adjust VOLTS/DIV and SEC/DIV settings.
Nuk u zbulua asnjë sinjal.Probe not connected, faulty probe, no signal from source.Ensure probe is securely connected. Test probe with known signal. Verify signal source is active.

8. Specifikimet

The following table details the technical specifications of the Hantek DSO2D10 Digital Storage Oscilloscope.

SpecifikimiVlera
ModelDSO2D10
Kanalet2 CH
Gjerësia e brezit100 MHz
Sample Norma1GSa/S
Thellësia e ruajtjes8 Mpts
Built-in Signal Source1CH (25MHz)
Rise Time at BNC (typical)3.5 NS
Lloji i ekranit7" TFT LCD, 800x480 pixels
Oscilloscope Size (L x W x H)318 x 140 x 150 mm
Dimensionet e paketës36.6 x 22.6 x 20.4 cm
Pesha2.77 kg
ProdhuesiHantek
Numri i pjesës së prodhuesitDSO2000
Burimi i energjisëKabllo Elektrike
NgjyraE zezë
Veprimi minimal Voltage300 volt
Specifikime në përputhjeCAT II, CE
GTIN / UPC768461092407

For a comparison with other models, refer to the table below:

Comparison table of Hantek oscilloscope models including DSO2D10

Figure 8: Model Comparison Table