1. Hyrje dhe Mbiview
The Vertiv Liebert GXT5 Lithium-Ion N Online UPS (Uninterruptible Power Supply) provides reliable, high-quality AC power to IT equipment. This unit is designed to protect critical loads from power disturbances and outages, ensuring continuous operation. Featuring Lithium-Ion battery technology, it offers extended battery life and reduced maintenance compared to traditional UPS systems. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your UPS.

Figura 1: Përpara view of the Vertiv Liebert GXT5 UPS, showing the display and ventilation.
2. Informacion mbi sigurinë
Ju lutemi lexoni dhe kuptoni të gjitha udhëzimet e sigurisë përpara se të instaloni, përdorni ose mirëmbani UPS-in. Mosndjekja e këtyre udhëzimeve mund të rezultojë në goditje elektrike, zjarr ose lëndime serioze.
- Rreziku elektrik: Kjo njësi përmban vëllime të rrezikshmetages. Do not open the UPS enclosure. Refer all servicing to qualified service personnel.
- Siguria e baterisë: The UPS contains Lithium-Ion batteries. Do not dispose of batteries in a fire. Batteries may explode. Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes.
- Tokëzimi: Ensure the UPS is properly grounded to reduce the risk of electric shock.
- Mjedisi: Install the UPS in a controlled environment, free from excessive dust, humidity, and extreme temperatures.
- Pesha: The UPS unit is heavy. Use proper lifting techniques or assistance during installation to prevent injury.
3. Përmbajtja e paketës
Verify that all items are present in the packaging. If any items are missing or damaged, contact your supplier.
- Vertiv Liebert GXT5 Lithium-Ion N Online UPS Unit
- Kordoni i energjisë së hyrjes
- Output Power Cords (quantity may vary)
- Kabllo USB
- Kablloja serike
- Rackmount Kit (rails, hardware)
- Tower Stands (for tower configuration)
- Udhëzues për fillimin e shpejtë dhe udhëzime sigurie
4. Konfigurimi
4.1 Instalimi fizik
The GXT5 UPS can be installed in either a rackmount or tower configuration.
Tower Configuration:
Attach the provided tower stands to the bottom of the UPS unit for stable vertical placement. Ensure adequate clearance for ventilation.

Figure 2: UPS unit configured for tower installation with stands.
Rackmount Configuration:
Install the rackmount rails into your standard 19-inch equipment rack. Slide the UPS unit onto the installed rails and secure it with the provided screws.
4.2 Connecting Power and Equipment
- Lidhni fuqinë hyrëse: Plug the UPS input power cord into a properly grounded electrical outlet.
- Lidhni pajisjet: Plug your critical equipment (servers, network devices, etc.) into the output receptacles on the rear panel of the UPS. Note that some outlets may be individually controllable.
- Portet e komunikimit: For monitoring and management, connect the USB or serial cable to your computer or network device.
- Optional RDU101 Card: If using the optional RDU101 network management card, insert it into the Intellislot and connect an Ethernet cable for remote monitoring.

Figure 3: Rear panel connections, including input power, output receptacles, and communication ports.

Figure 4: RDU101 network management card with labeled ports.
4.3 Ndezja fillestare
After all connections are secure, press the power button on the front panel to turn on the UPS. The display will illuminate, and the UPS will perform a self-test. Allow the batteries to charge for at least 24 hours before relying on them for extended backup time.
5. Operimi i UPS-it
5.1 Front Panel Display and Controls
Ekrani LCD i panelit të përparmë ofron informacion në kohë reale për statusin, duke përfshirë volumin e hyrjes/daljes.tage, load level, battery status, and alarm conditions. Use the navigation buttons to access menus and configure settings.
5.2 Mënyrat e funksionimit
- Modaliteti në internet: Normal operation where the UPS continuously converts AC input to DC to charge batteries and then back to AC to power connected equipment, providing maximum protection.
- Modaliteti i baterisë: When input power fails, the UPS automatically switches to battery power to keep connected equipment running.
- Modaliteti i anashkalimit: In certain conditions or for maintenance, the UPS can transfer the load directly to utility power, bypassing the UPS's power conditioning.
5.3 Procedurat e Mbylljes
To safely shut down the UPS, first power off all connected equipment. Then, press and hold the power button on the UPS front panel until the unit powers off. Disconnect the input power cord only after the UPS is completely off.
6. Mirëmbajtja
6.1 Kujdesi për baterinë
The Lithium-Ion batteries in your GXT5 UPS are designed for a long service life. Regular maintenance is generally not required. However, ensure the UPS operates within recommended temperature ranges to maximize battery lifespan. Avoid frequent deep discharges if possible.
6.2 Pastrimi
Keep the UPS free from dust and debris. Use a soft, dry cloth to clean the exterior. Do not use liquid cleaners or solvents. Ensure ventilation openings are clear and unobstructed.
6.3 Përditësimet e firmuerit
Periodically check the Vertiv website for available firmware updates for your UPS model. Firmware updates can provide performance enhancements, bug fixes, and new features. Follow the instructions provided with the update package carefully.
7. Troubleshooting
This section provides solutions to common issues you may encounter with your UPS. For more complex problems, contact Vertiv technical support.
| Problem | Shkaku i mundshëm | Zgjidhje |
|---|---|---|
| UPS nuk ndizet | No input power; Battery deeply discharged; Power button not pressed correctly. | Check input power cord connection and wall outlet. Allow UPS to charge for several hours. Press and hold power button for 2-3 seconds. |
| UPS bën një bip të vazhdueshëm | On battery power; Overload condition; Battery fault. | Check input power. Reduce connected load. Check battery status on display. |
| Pajisjet e lidhura humbin energjinë | UPS battery depleted; UPS shut down due to overload; UPS fault. | Check UPS display for error messages. Ensure load is within UPS capacity. |
8. Specifikimet
| Veçori | Specifikimi |
|---|---|
| Numri i modelit | GXT5LI-1500LVRT2UXLN |
| Kapaciteti (VA/Watts) | 1500 VA / 1350 W |
| Volumi i hyrjestage | 120 volt |
| Lloji i baterisë | Jon litium |
| Dimensionet e produktit (J x P x H) | 24 x 22.5 x 9.5 inç |
| Pesha e artikullit | 55.4 paund |
| Ngjyra | E zezë |
9. Garancia dhe Mbështetja
Your Vertiv Liebert GXT5 UPS is covered by a manufacturer's warranty. Please refer to the warranty card included with your product or visit the official Vertiv webfaqe interneti për kushtet dhe afatet e detajuara të garancisë.
For technical assistance, troubleshooting, or to inquire about service, please contact Vertiv customer support. You can also explore additional resources and product information through the Vertiv Virtual Showroom:
Visit the Vertiv Virtual Showroom

Figure 5: Scan this QR code to access the Vertiv Virtual Showroom for more product information and support.