Yonker Manuals & User Guides
Yonker specializes in portable medical testing devices, including infrared thermometers, pulse oximeters, fetal dopplers, and phototherapy instruments.
About Yonker manuals on Manuals.plus
Yonker is a manufacturer of portable medical devices and health monitoring equipment designed for both clinical and home use.
Their product lineup includes non-contact infrared forehead thermometers for hygienic temperature readings, fingertip pulse oximeters for measuring blood oxygen saturation, fetal dopplers for monitoring fetal heart rates, and specialized portable UVB phototherapy instruments for treating skin conditions like vitiligo and psoriasis. Yonker focuses on delivering accurate, easy-to-use health tools with features like smart analysis, acousto-optic prompts, and compact designs to empower patients and medical professionals alike.
Yonker manuals
Manualet më të fundit nga manuals+ të kuruara për këtë markë.
Manuali i përdoruesit yonker YK-80A Fingertip Pulse Oximeter
Manuali i përdorimit të termometrit infra të kuqe YK-IRT2 yonker
Yonker YK-ER6 ECG Recorder Instruction Manual
Manuali i Përdoruesit të Oksimetrit të Pulsit Yonker me Majë Gishtash - Modeli YK-80A deri në YK-84C
Udhëzime për Monitorin Qendror - Yonker
Manuali i Përdorimit të Termometrit me Infra të Kuqe Yonker YK-IRT2
Manuali i përdorimit të Pulse Oximeter në majë të gishtave
Manuali i Përdorimit të Termometrit me Infra të Kuqe Yonker YK-IRT2
Yonker manuals from online retailers
YONKER Fetal Doppler YK 90 B Instruction Manual
Yonker YK Series Fingertip Pulse Oximeter User Manual
Yonker YK-6000A UVB Phototherapy Instrument User Manual
Yonker video guides
Shikoni videot e konfigurimit, instalimit dhe zgjidhjes së problemeve për këtë markë.
Yonker support FAQ
Pyetje të zakonshme në lidhje me manualet, regjistrimin dhe mbështetjen për këtë markë.
-
How do I take an accurate reading with a Yonker infrared thermometer?
Aim the sensor at the middle of the forehead above the eyebrows, keep it under 5 cm away without touching the skin, and press the start/trigger button. Ensure the forehead is free of hair, sweat, and cosmetics before measuring.
-
What does 'Lo' or 'Hi' mean on my Yonker thermometer?
'Lo' means the measured temperature is below 34.0°C (93.2°F), while 'Hi' signifies the temperature is above 43.0°C (109.4°F). Try taking the measurement again in a stable room temperature, adhering to proper guidelines.
-
How can I change the units from Celsius to Fahrenheit on my Yonker device?
Depending on the model, you can normally press and hold the 'MODE' or start button from a shutdown state until the unit screen changes, or enter the 'F1' setup menu to switch between °C and °F using the up/down keys.
-
What should I do if my Yonker pulse oximeter isn't reading correctly?
Ensure your finger is inserted completely into the rubber hole with the nail facing upward. Also check that you are not trembling your finger, your nails are not painted with polish, and the batteries have sufficient power.