Leviton 8200-LW

Leviton 8200-LW 15-Amp 125-Volt Hospital Grade Duplex Receptacle Instruction Manual

Model: 8200-LW

1. Hyrje

This manual provides instructions for the safe installation, operation, and maintenance of the Leviton 8200-LW 15-Amp, 125-Volt, Hospital Grade Duplex Receptacle. Please read these instructions thoroughly before beginning installation and retain them for future reference.

Leviton 8200-LW 15-Amp 125-Volt Hospital Grade Duplex Receptacle, White

Imazhi 1: Përpara view of the Leviton 8200-LW Hospital Grade Duplex Receptacle in White.

2. Informacion i rëndësishëm për sigurinë

PARALAJMËRIM: PËR TË SHMANGUAR ZJARRI, GRONDJA APO VDEKJA; FIKONI FREZIKEN NË NDËRPRESËSIN APO SIGURALËT DHE PROVO SE FYKËSIA ËSHTË FIKË PARA LINDJES!

3. Përmbajtja e paketës

The package for the Leviton 8200-LW Duplex Receptacle typically includes:

4. Specifikimet e produktit

Numri i modelit: 8200-LW
Ampegërsi: 15 Amps
Vëlltage: 125 volt
Konfigurimi: 5-15R
Lidhja elektrike: 3-Wire, Self-Grounding (Back and Side Wiring)
Polakët: 2-Pole
Materiali: Nylon (Body/Face)
Ngjyra: E bardha
Miratime: UL, CSA C22.2, NOM 057
Lloji: Heavy Duty, Hospital Grade

5. Konfigurimi dhe instalimi

Mjetet e nevojshme: Screwdriver (Phillips and/or Flathead), Wire Strippers, Electrical Tape, Voltage Tester.

  1. Fikni energjinë: Locate the circuit breaker or fuse that controls the outlet you are replacing or installing. Turn off the power and verify it is off using a voltage testues.
  2. Remove Old Receptacle (if applicable): Unscrew the wall plate and then the mounting screws holding the old receptacle in the electrical box. Carefully pull the old receptacle out of the box.
  3. Shkëputni telat: Note the position of each wire before disconnecting. Typically:
    • Green or Bare Copper Wire: Teli i tokëzimit.
    • Teli i bardhë: Teli neutral.
    • Black or Red Wire: Hot (live) wire.
    Loosen the terminal screws and remove the wires.
  4. Përgatitni telat: If necessary, strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the wires. Ensure the wire ends are clean and straight.
  5. Connect Wires to New Receptacle: The Leviton 8200-LW supports both back and side wiring.
    • Tel Tokëzimi (Bakri i Gjelbër ose i Zhveshur): Connect to the green hexagonal ground screw.
    • Tel Neutral (i Bardhë): Connect to the silver terminal screws.
    • Tel i nxehtë (i zi ose i kuq): Connect to the brass terminal screws.

    For Side Wiring: Loop the wire clockwise around the screw terminal and tighten securely. Ensure no bare wire is exposed outside the terminal.

    For Back Wiring: Insert the stripped wire end into the appropriate hole on the back of the receptacle and tighten the corresponding screw on the side. The V-shaped, serrated back-wiring clamps ensure superior contact.

  6. Enë e sigurt: Carefully fold the wires into the electrical box. Insert the new receptacle into the box and secure it with the mounting screws.
  7. Instaloni pllakën e murit: Attach the wall plate over the receptacle.
  8. Rivendosni energjinë: Turn the power back on at the circuit breaker or fuse.
  9. Test: Test the receptacle with a known working device.

6. Udhëzimet e funksionimit

The Leviton 8200-LW Duplex Receptacle functions as a standard electrical outlet. Once properly installed and powered, simply insert the plug of your electrical device into one of the two available outlets. Ensure the plug is fully inserted for a secure connection.

7. Mirëmbajtja

8. Troubleshooting

Problem Shkaku i mundshëm Zgjidhje
Nuk ka energji në enë. Ndërprerësi i qarkut është shkëputur ose siguresa është djegur. Lidhje e lirshme e instalimeve elektrike. Check and reset the circuit breaker or replace the fuse. Turn off power and check all wire connections for tightness.
Plug feels loose in the receptacle. Worn receptacle contacts (unlikely for new hospital-grade). Incorrect plug type. Ensure the plug is fully inserted. If the issue persists with multiple devices, consult a qualified electrician for inspection.
Receptacle is hot to the touch. Overload on the circuit. Loose connection. Faulty device. Immediately disconnect power. Reduce the load on the circuit. Have a qualified electrician inspect the wiring and device.

9. Garancia dhe Mbështetja

Leviton products are manufactured to the highest quality standards. For specific warranty information and customer support, please refer to the documentation included with your purchase or visit the official Leviton webfaqe interneti. Ruajeni faturën e blerjes si provë të blerjes.

Leviton Customer Support:

Dokumente të Ngjashme - 8200-LW

Paraview Prizë Leviton GFCI me porta USB Manuali i instalimit dhe përdorimit
Udhëzues gjithëpërfshirës për instalimin dhe funksionimin e prizave Leviton GFCI me porta USB, duke përfshirë udhëzimet për instalime elektrike, paralajmërimet e sigurisë, procedurat e testimit dhe informacionin e garancisë.
Paraview Instalimi dhe Testimi i Leviton Smart GFCI Outlet: Një Udhëzues Gjithëpërfshirës
Udhëzime hap pas hapi për instalimin dhe testimin e prizave Leviton Smart GFCI (modelet D2GF1, D2GF2). Mësoni rreth funksionalitetit të GFCI, instalimeve elektrike, zgjidhjes së problemeve dhe masave paraprake të sigurisë.
Paraview Udhëzues për instalimin dhe testimin e prizës Leviton SmartlockPro GFCI
Udhëzues gjithëpërfshirës për instalimin dhe testimin e prizave të Ndërprerësit të Qarkut të Gabimit të Tokëzimit (GFCI) Leviton SmartlockPro. Mbulon masat paraprake të sigurisë, instalimet elektrike, zgjidhjen e problemeve dhe veçoritë e produktit.
Paraview Udhëzues për instalimin dhe testimin e prizës Leviton GFCI
Një udhëzues gjithëpërfshirës se si të instaloni dhe testoni një prizë Leviton SmartLock Pro GFCI, duke përfshirë udhëzimet për instalime elektrike, masat paraprake të sigurisë dhe këshilla për zgjidhjen e problemeve.
Paraview Udhëzues për Përzgjedhjen e Çelësave të Klasit Komercial dhe Industrial Leviton
Një udhëzues gjithëpërfshirës përzgjedhjeje nga Leviton që detajon çelësat e gradës komerciale dhe industriale, duke përfshirë llojet e çelësave me çelës, Decora Plus, Lev-lok, antimikrobikë dhe çelësa specialë me detaje aplikimi dhe diagrame instalimesh elektrike.
Paraview Udhëzues për instalimin e prizës Leviton GFNT1-DIN/GFNT2-DIN për montim në shinë DIN GFCI
Udhëzues gjithëpërfshirës për instalimin dhe testimin e prizave GFCI të montuara në shinë GFNT1-DIN dhe GFNT2-DIN të Leviton, duke përfshirë udhëzimet për instalime elektrike, masat paraprake të sigurisë dhe zgjidhjen e problemeve.