Trane PSE-T19

Manuali i Udhëzimeve për Sensorin e Flakës së Furrës Trane PSE-T19

Model: PSE-T19 (Part Number: SEN01114_v4)

1. Hyrje

This manual provides essential information for the proper installation, operation, maintenance, and troubleshooting of the Trane Furnace Flame Sensor, model PSE-T19. This component is a critical safety device designed to ensure the safe and efficient operation of your furnace. Please read this manual thoroughly before attempting any procedures.

2. Informacion mbi sigurinë

PARALAJMËRIM: Instalimi, rregullimi, ndryshimi, shërbimi ose mirëmbajtja jo e duhur mund të shkaktojë dëmtim të pronës, lëndim ose vdekje. Lexoni plotësisht udhëzimet e instalimit, funksionimit dhe mirëmbajtjes përpara se të instaloni ose servisoni këtë pajisje.

  • Always disconnect electrical power to the furnace before performing any service or maintenance.
  • Working with gas appliances can be hazardous. If you are not qualified to perform these procedures, contact a certified HVAC technician.
  • Vishni pajisje mbrojtëse personale (PMP) të përshtatshme, siç janë dorezat dhe mbrojtëset e syve.
  • Ensure all gas connections are properly sealed and tested for leaks after any work involving gas lines.
  • Mos anashkaloni asnjë pajisje sigurie.

3. Produkti i Mbaruarview

The flame sensor is a safety device in a gas furnace that detects the presence of a flame in the burner assembly. If the sensor does not detect a flame after the gas valve opens, it signals the furnace control board to shut off the gas supply, preventing unburnt gas from accumulating. This specific sensor is an upgraded replacement for Trane part number SEN01114.

Image of the Trane Furnace Flame Sensor PSE-T19

Figure 1: Trane Furnace Flame Sensor PSE-T19
This image displays the Trane Furnace Flame Sensor PSE-T19. It features a white ceramic insulator body, a metal mounting bracket with a screw hole, and a metal rod that extends into the flame path to detect the presence of a flame.

4. Konfigurimi dhe instalimi

Installation of the flame sensor should only be performed by a qualified technician. The following steps are for informational purposes only.

  1. Shkëputni energjinë: Fikeni të gjithë energjinë elektrike në furrën në panelin kryesor të shërbimit.
  2. Gjeni vendndodhjen e sensorit: Identify the existing flame sensor. It is typically a single metal rod positioned in the flame path of the burner assembly, often secured by one screw.
  3. Hiqni sensorin e vjetër: Carefully disconnect the wire leading to the sensor. Remove the screw holding the sensor in place and gently pull the old sensor out.
  4. Instaloni një sensor të ri: Insert the new Trane PSE-T19 flame sensor into the same position. Ensure the metal rod is correctly positioned to be enveloped by the flame during operation. Secure it with the mounting screw.
  5. Lidhni instalimet elektrike: Reconnect the wire to the new flame sensor. Ensure the connection is secure.
  6. Rivendosni energjinë: Ndizni energjinë elektrike në furrë.
  7. Operacioni i testimit: Initiate a heating cycle and observe the furnace's ignition sequence. The main burners should ignite and remain lit.

5. Parimet e Operimit

When the furnace calls for heat, the igniter heats up, and the gas valve opens. As the gas ignites, the flame sensor, which is a small metal rod, becomes exposed to the flame. The flame rectifies a small alternating current (AC) into a direct current (DC) signal. This DC signal is sent to the furnace's control board, confirming the presence of a flame. If the control board does not receive this signal within a few seconds of ignition, it will shut off the gas supply as a safety measure, preventing unburnt gas from accumulating in the combustion chamber.

6. Mirëmbajtja

Regular maintenance of the flame sensor is crucial for reliable furnace operation. A dirty flame sensor is a common cause of furnace malfunctions.

  • Pastrimi: Annually, or if experiencing ignition issues, carefully remove the flame sensor. Use fine-grit sandpaper or steel wool to gently clean off any carbon buildup or oxidation from the ceramic insulator and the metal rod. Do not use harsh chemicals or abrasive cleaners that could damage the sensor.
  • Inspektimi: While cleaning, inspect the sensor for any signs of physical damage, such as cracks in the ceramic, corrosion, or a bent rod. Replace the sensor if any damage is observed.
  • Riinstalimi: Reinstall the cleaned sensor, ensuring it is securely mounted and the wire connection is tight.

7. Troubleshooting

If your furnace is experiencing issues related to ignition or short cycling, the flame sensor may be a contributing factor.

  • Furnace Ignites, then Shuts Off (Short Cycling): This is a classic symptom of a dirty or faulty flame sensor. The sensor detects the flame initially but then loses the signal, causing the furnace to shut down.
  • Furnace Fails to Ignite: While many factors can cause this, a completely failed flame sensor can prevent the furnace from even attempting to keep the gas valve open.

Hapat e zgjidhjes së problemeve:

  1. Clean the Flame Sensor: Follow the cleaning instructions in Section 6. This resolves most flame sensor-related issues.
  2. Kontrolloni instalimet elektrike: Ensure the wire connecting the flame sensor to the control board is secure and free from damage.
  3. Inspektoni për dëmtime: Look for any visible damage to the sensor itself.
  4. Test for Continuity (Advanced): A qualified technician can use a multimeter to test the sensor's continuity and signal output.
  5. Zëvendësoni sensorin: If cleaning and inspection do not resolve the issue, and the sensor is suspected to be faulty, replace it with a new Trane PSE-T19 or equivalent part.

8. Specifikimet

atributVlera
Numri i modelitPSE-T19 (SEN01114_v4)
ProdhuesiTrane
Dimensionet e produktit6 x 6 x 6 inç
Pesha e artikullit0.53 ons
ASINB00ECEERIG

9. Informacioni i garancisë

Warranty coverage for the Trane Furnace Flame Sensor PSE-T19 is typically provided by the seller or manufacturer at the time of purchase. Please refer to your purchase documentation or contact the original point of sale for specific warranty terms and conditions.

10. Mbështetje

For technical assistance, installation guidance, or troubleshooting beyond the scope of this manual, please contact the seller or a qualified HVAC professional. Ensure you have your product model number (PSE-T19 or SEN01114_v4) and purchase details available when seeking support.

Dokumente të Ngjashme - PSE-T19

Paraview Furrë me gaz horizontale Trane XL 80 me rrjedhje lart/poshtë: Specifikimet dhe karakteristikat
Udhëzues gjithëpërfshirës për furrat me gaz Trane XL 80 seri (modelet TUD2 dhe TDD2), duke detajuar karakteristikat, të dhënat e performancës, specifikimet elektrike dhe dimensionet për instalimet me rrjedhje lart, poshtë dhe horizontale.
Paraview Manuali i Instalimit, Funksionimit dhe Mirëmbajtjes së Furrës me Gaz të Serisë Standarde S8 të Trane & American
Udhëzues gjithëpërfshirës për instalimin, funksionimin dhe mirëmbajtjen e Trane dhe serisë American Standard S8 Upflow/Downflow/Horizontal Gas-Fired 1-Stage dhe 2-StagFurra me tërheqje të induktuar me motor me efikasitet të lartë. Përfshin paralajmërime sigurie, specifikime, diagrama instalimesh elektrike dhe zgjidhje problemesh.
Paraview Furrë me gaz Trane XT95 me efikasitet të lartë: Specifikimet dhe karakteristikat
Të dhëna të detajuara të produktit, veçoritë, përfitimet, specifikimet, të dhënat e performancës, diagramet e instalimeve elektrike dhe dimensionet për serinë Trane XT95 të pajisjeve me efikasitet të lartë, me një spërkatës.tage, furra me gaz me kondensim, me ndihmën e ventilatorit, me ventilim të drejtpërdrejtë.
Paraview Buletini i Shërbimit të Dështimeve të Bordit të IFC-së Trane & American Standard - Ripërpunim i DETYRUAR
Buletin zyrtar shërbimi nga Trane dhe American Standard në lidhje me defektet e bordit të Kontrollit të Integruar të Furrës (IFC) në modele specifike të furrave. Detajet e kodit të gabimit 5, modelet e prekura dhe udhëzimet e detyrueshme të ripërpunimit.
Paraview Furra me gaz Trane S9V2 Seria: Manuali i instalimit, funksionimit dhe mirëmbajtjes
Udhëzues gjithëpërfshirës për instalimin, funksionimin dhe mirëmbajtjen e Trane dhe serisë 2 të American Standard S9V2tagFurrat me gaz me kondensim dhe shpejtësi të ndryshueshme. Mbulon sigurinë, procedurat e instalimit, specifikimet dhe zgjidhjen e problemeve.
Paraview Trane S9V2 Series Two Stage Condensing Gas Fired Furnace Product Data
Detailed product data and specifications for the Trane S9V2 Series Two Stage Condensing Gas Fired Furnace, covering features, benefits, model variations, technical specifications, and airflow performance tables.