1. Hyrje
This manual provides essential information for the safe and efficient operation of your Green Cell INV07 Pure Sine Wave Inverter with UPS function. This device converts 12V DC power from a battery into 230V AC power, suitable for a wide range of electronic devices. It also features an Uninterruptible Power Supply (UPS) function, ensuring continuous power for critical applications like central heating pumps during outages.
The inverter delivers a continuous output of 300W and a peak power of up to 600W. It is designed for devices requiring a stable, pure sine wave power supply, similar to standard wall outlets.
2. Udhëzimet e sigurisë
- Lexoni të gjitha udhëzimet: Përpara se të vini në punë inverterin, lexoni dhe kuptoni të gjitha udhëzimet e sigurisë dhe të funksionimit.
- Ventilimi: Sigurohuni që të ketë ventilim të mjaftueshëm përreth inverterit. Mos i bllokoni hapjet e ventilimit.
- Shmangni lagështinë: Do not expose the inverter to rain, water, or excessive humidity.
- Tokëzimi i duhur: Always connect the inverter to a properly grounded 12V DC power source.
- Mbrojtja nga mbingarkesa: Do not exceed the inverter's rated continuous power output (300W) or peak power (600W). Overloading can damage the inverter and connected devices.
- Lidhja e baterisë: Connect the inverter directly to a 12V battery using the provided cables. The nominal line for cigarette lighter connection is limited to a maximum of 150W.
- Vëllim i lartëtage: The inverter produces high AC voltage. Treat it with the same caution as a standard wall outlet.
- Fëmijët dhe kafshët shtëpiake: Mbajeni invertorin larg fëmijëve dhe kafshëve shtëpiake.
- Mirëmbajtja: Only qualified personnel should perform maintenance or repairs.
3. Përmbajtja e paketës
Verifikoni që të gjitha sendet janë të pranishme në paketim:
- Green Cell INV07 Pure Sine Wave Inverter with UPS
- Kabllot e lidhjes së baterisë (të kuqe për pozitive, të zeza për negative)
- Siguresat rezervë
- Manuali i Përdoruesit

Image: Green Cell INV07 Inverter and its included accessories: battery cables, spare fuses, and the user manual.
4. Produkti i Mbaruarview
Familiarize yourself with the inverter's components and ports.
Paneli i përparmë

Image: Front panel with AC output, USB port, power switch, and status indicators.
- Priza e daljes AC: For connecting 230V AC devices.
- Porta USB: For charging smaller devices like smartphones and tablets.
- Ndërprerësi i energjisë (ON/FIK): To turn the inverter on or off.
- Treguesi i energjisë (LED jeshile): Illuminates when the inverter is operating normally.
- Fault Indicator (Red LED): Illuminates to indicate an error or fault condition.
- Hyrja AC: For connecting to a 230V AC mains supply when using the UPS function.
Paneli i pasmë

Image: Rear panel with DC input terminals and cooling fan.
- DC Input Terminals (+ and -): For connecting to a 12V DC battery. Ensure correct polarity (red for +, black for -).
- Ventilator ftohës: Automatically activates to dissipate heat during operation.
5. Konfigurimi
Follow these steps to set up your Green Cell INV07 inverter:
- Vendosja: Choose a dry, well-ventilated location for the inverter, away from direct sunlight, heat sources, and flammable materials. Ensure sufficient space for airflow around the cooling fan.
- Lidhja e baterisë:
- Connect the red cable to the positive (+) terminal of your 12V battery and the positive (+) DC input terminal on the inverter.
- Connect the black cable to the negative (-) terminal of your 12V battery and the negative (-) DC input terminal on the inverter.
- Ensure connections are tight and secure to prevent arcing or overheating.
- AC Mains Connection (for UPS function): If you intend to use the UPS function, connect the inverter's AC input to a standard 230V AC wall outlet using a suitable power cord.
- Lidhja e pajisjes: Ensure the inverter's power switch is in the OFF position before connecting any devices. Plug your 230V AC devices into the AC output socket and/or USB devices into the USB port.

Imazhi: Sipër view of the inverter, illustrating its compact design and connection points.
6. Udhëzimet e funksionimit
- Ndezja: After all connections are secure, switch the inverter's power switch to the ON position. The green Power LED should illuminate, indicating normal operation.
- Pajisjet e lidhjes: You can now power your 230V AC devices (up to 300W continuous, 600W peak) and charge USB devices.
- Funksioni i UPS: If the inverter is connected to both a 12V battery and a 230V AC mains supply, it will automatically switch to battery power in case of a mains power outage, providing an uninterrupted power supply to connected devices. When mains power is restored, it will switch back and recharge the battery.
- Fike: Before disconnecting any devices or the inverter from the battery, switch the inverter's power switch to the OFF position.
7. Mirëmbajtja
- Pastrimi: Regularly clean the inverter's exterior with a dry, soft cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
- Kontrolli i lidhjes: Periodically check all electrical connections (battery terminals, AC input/output) to ensure they are tight and free from corrosion.
- Ndërrimi i siguresave: If the inverter stops working due to an internal fault, check the fuses. Replace blown fuses only with fuses of the same type and rating (e.g., 30A). Refer to the manual or product labeling for specific fuse ratings.
- Shëndeti i baterisë: Ensure the connected 12V battery is in good condition and adequately charged for optimal inverter performance.
8. Troubleshooting
| Problem | Shkaku i mundshëm | Zgjidhje |
|---|---|---|
| No power output / Inverter does not turn on | Loose battery connection, discharged battery, blown fuse, inverter fault. | Check battery connections. Recharge or replace battery. Check and replace fuses if necessary. If problem persists, contact support. |
| Red Fault LED illuminates / Inverter beeps | Overload, short circuit, over-temperature, low battery voltage, vëllimi i lartë i baterisëtage. | Reduce connected load. Check for short circuits in connected devices. Ensure proper ventilation. Check battery voltage. Allow inverter to cool down. |
| Fan is noisy or constantly running | High internal temperature due to heavy load or insufficient ventilation. | This is normal operation under load. Ensure adequate ventilation. Reduce load if fan runs excessively. |
| Devices not working correctly (e.g., mini-fridge beeping) | Device power requirement exceeds inverter capacity, or device is sensitive to power fluctuations. | Verify the power consumption of your device. Ensure it does not exceed 300W continuous. Some devices have high startup (surge) power requirements. |
9. Specifikimet
| Veçori | Specifikimi |
|---|---|
| Markë | Qeliza e Gjelbër |
| Model | INV07 (Green Cell PRO) |
| Fuqia e vazhdueshme | 300 W |
| Surge Power (Peak) | 600 W |
| Vëllimi i hyrjes DCtage | 12 V |
| Dalja AC Voltage | 230 V |
| Forma e valës së daljes | Vala e pastër e sinusit |
| Frekuenca | 50 Hz |
| Funksioni UPS | Yes, with Power Bypass |
| Dalje USB | po |
| Dimensionet (J x P x H) | 31 x 18 x 7.5 cm |
| Pesha | 2 kg |
| Recommended Battery Capacity (for UPS) | 30 Amp-hours (minimum, larger for longer runtime) |
| Pajisjet e përputhshme | Car, Laptop, devices requiring pure sine wave power |
10. Garancia dhe Mbështetja
Green Cell products are designed for reliability and performance. For warranty information, please refer to the documentation provided with your purchase or visit the official Green Cell website. If you encounter any issues or require technical assistance, please contact Green Cell customer support through their official channels. Ensure you have your product model (INV07) and purchase details available when contacting support.