
SoliTek SOLID Series Solar Modules

Udhëzimet e përdorimit
- Read this guide entirely before installation.
- This document provides minimum requirements and recommendations for safe and successful installation of SoliTek PV modules and is necessary to retain compliance with IEC 61215, IEC 61730, and UL 61730 standards.
- This guide provides basic information on JSC SoliTek Cells SOLID series photovoltaic modules, including their installation and safe handling.
- All instructions should be read and understood before attempting installation. Contact your dealer or JSC SoliTek Cells for further information if needed.
- This documentation refers to the PV modules themselves and is not a comprehensive installation manual for personnel not specifically trained in PV modules.
- It serves as a general but strictly mandatory reference for the installer. Infringement or inaccurate observance of any clause in this documentation voids the warranty.
- The installer must understand and follow all applicable local, state, and federal regulations and standards for building construction, electrical design, fire, and safety.
- Check with local authorities for permitting requirements before installing or maintaining PV modules, and become familiar with mechanical and electrical requirements for photovoltaic systems.
- Mosndjekja e udhëzimeve në këtë udhëzues mund të dëmtojë komponentët e sistemit, të rrezikojë personelin, të dëmtojë pronën ose të zhvlerësojë garancinë e panelit.
- Rooftop PV systems should only be installed on dwellings formally analyzed for structural integrity and confirmed to be capable of handling the additional weighted load of PV system components (including PV modules) by a certified building specialist or engineer.
KËRKESAT E PËRGJITHSHME
- Ju lutemi lexoni këtë udhëzues tërësisht përpara instalimit.
- Qëllimi i këtij dokumenti është të ofrojë kërkesat dhe rekomandimet minimale për instalimin e sigurt dhe të suksesshëm të moduleve PV Solitek.
- Ky dokument përmban gjithashtu kërkesat e nevojshme për të ruajtur përputhjen e modulit PV të Solitek me standardet IEC 61215, IEC 61730, UL 61730.
- Ky udhëzues përmban informacion bazë në lidhje me modulet fotovoltaike të serisë SOLID të S.A. “SoliTek Cells”, instalimin dhe trajtimin e sigurt të tyre. Të gjitha udhëzimet duhet të lexohen dhe kuptohen përpara se të tentoni instalimin. Nëse keni ndonjë pyetje, ju lutemi kontaktoni shitësin tuaj ose S.A. “SoliTek Cells” për më shumë informacion.
- This documentation refers to the PV-modules themselves and is not meant to be a complete installation manual for personnel not specifically trained to PV-modules.
- It serves as a general but strictly mandatory reference for the Installer.
- Shkelja ose respektimi i pasaktë i ndonjë klauzole të këtij dokumentacioni anulon garancinë.
- Instaluesi duhet të kuptojë dhe të ndjekë të gjitha rregulloret dhe standardet e zbatueshme lokale, shtetërore dhe federale për ndërtimin e ndërtesave, projektimin elektrik, zjarrin dhe sigurinë, dhe duhet të kontrollojë me autoritetet lokale për të përcaktuar kërkesat e zbatueshme të lejeve përpara se të përpiqet të instalojë ose mirëmbajë modulet FV dhe duhet të njihen me kërkesat mekanike dhe elektrike për sistemet fotovoltaike.
- Mosrespektimi i udhëzimeve në këtë udhëzues mund të dëmtojë komponentët e sistemit, të rrezikojë personelin, të dëmtojë pronën ose të zhvlerësojë garancinë e panelit.
- Sistemet FV në tavanë duhet të instalohen vetëm në banesa që janë analizuar zyrtarisht për integritetin strukturor dhe janë konfirmuar se janë në gjendje të përballojnë ngarkesën e peshuar shtesë të komponentëve të sistemit FV, duke përfshirë modulet FV, nga një specialist ose inxhinier i certifikuar ndërtimi.
- For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken, including, without limitation fall protection measures, ladders or stairways, and personal protective equipment (PPE).
- For your safety, do not install or handle PV modules under adverse conditions, including, without limitation strong or gusty winds, and wet or frosted roof surfaces.
- Ndërtimi i modulit PV me pllakë të sheshtë përbëhet nga një montim i laminuar i qelizave diellore të mbyllura brenda një materiali izolues brenda dy fletëve xhami.
- Mbajeni këtë dokumentacion në një vend të sigurt për referencë në të ardhmen.
- Mos u përpiqni të çmontoni modulin dhe mos hiqni asnjë pllakë emri ose përbërës të bashkangjitur! Duke vepruar kështu do të anuloni garancinë.
Trajtimi & Aplikimi
TRAJTIMI
- SoliTek PV modules must be transported in the supplied packaging only and kept in the packaging until they are ready to be installed.
- Protect pallets against movement and exposure to damage during transportation. Secure pallets from falling over.
- Mos e tejkaloni lartësinë maksimale të paletave që do të grumbullohen, siç tregohet në paketimin e paletës.
- Store pallets in a cool and dry location until the PV modules are ready to be unpackaged.
- SoliTek PV modules are heavy and should be handled with care. Never use the junction box or cables as a grip.
- Do not exert mechanical stress on the cables.
- Never step on PV modules or drop or place heavy objects on them.
- Be careful when placing PV modules on hard surfaces and secure them from falling.
- Broken glass can result in personal injury. PV modules with broken glass cannot be repaired and must not be used.
- Broken or damaged PV modules must be handled carefully and disposed of properly.
APLIKACIONI
Kufizimet
- SoliTek PV modules must be mounted on appropriate mounting structures positioned on suitable buildings, the ground, or other structures suitable for PV modules (e.g. carports, building facades or PV trackers).
- PV modules must not be mounted on moving vehicles of any kind. Modules must not be installed in locations where they could be submerged in water.
- Do not install modules above 2000 m (6561 ft) altitude above sea level
- Drita e përqendruar artificialisht nuk duhet të drejtohet në modulet SoliTek PV.
Rekomandime
- SoliTek rekomandon që modulet PV të montohen në një kënd animi minimal prej 10 gradë për të lejuar vetëpastrimin e duhur nga shiu.
- Hija e pjesshme ose e plotë e një moduli ose moduleve PV mund të zvogëlojë ndjeshëm performancën e sistemit.
- SoliTek rekomandon minimizimin e sasisë së hijes gjatë gjithë vitit për të rritur sasinë e energjisë së prodhuar nga modulet FV.
- Sistemi i lartë voltages could be induced in the event of an indirect lightning strike, which could cause damage to PV system components.
- The open area of wire loops should be minimized in order to reduce the risk of lightning-induced voltage rritet.
- Ventilimi më i mirë i modulit dhe kabllot më të shkurtër të lidhjes rrisin prodhimin e energjisë elektrike.
Për modulet bifaciale:
- Rekomandohet të rritet lartësia e panelit PV nga toka në mënyrë që më shumë dritë të kalojë poshtë modulit dhe më pas të reflektojë
- Fitimi bifacial rritet ndjeshëm nëse modulet instalohen mbi sipërfaqe të bardha (vlerë e lartë albedo), që reflektojnë dritën.
Instalim elektrik
SIGURIA
- Modulet PV mund të prodhojnë rrymë dhe vëllimtage kur ekspozohet ndaj dritës së çdo intensiteti. Rryma elektrike rritet me intensitet më të lartë të dritës. DC voltage prej 50 Volt ose më e lartë është potencialisht vdekjeprurëse. Kontakti me qarkun e ndezur të një sistemi FV që funksionon nën dritë mund të rezultojë në goditje elektrike vdekjeprurëse.
- Çaktivizoni modulet PV duke i hequr ato tërësisht nga drita ose duke mbuluar sipërfaqen e përparme të tyre me një material të errët. Lidhur me rregullat e sigurisë për pajisjet elektrike të ndezura gjatë punës me module që janë të ekspozuara ndaj çdo drite. Përdorni mjete të izoluara dhe mos vishni bizhuteri metalike gjatë punës me modulet FV.
- Për të shmangur harkun dhe goditjen elektrike, mos i shkëputni lidhjet elektrike nën ngarkesë. Lidhjet e gabuara mund të rezultojnë gjithashtu në hark dhe goditje elektrike. Mbani lidhësit të thatë dhe të pastër dhe sigurohuni që ato të jenë në gjendjen e duhur të punës. Asnjëherë mos futni objekte metalike në lidhës dhe mos i modifikoni ato në asnjë mënyrë për të siguruar një lidhje elektrike.
- Do not touch or handle PV modules with broken glass unless the PV modules are first disconnected, and you are wearing proper PPE. Avoid handling PV modules when they are wet unless cleaning the PV modules as directed in this manual. Never touch electrical and wet connections without protecting yourself with insulated gloves.
- The modules are qualified for Class II protection against electrical shock, in accordance with clause 4 of IEC 61730-1:2016, which can be used in systems operating at > 50 V DC or >240 W, where general contact access is anticipated and modules qualified for safety through UL 61730 within this application class are considered to meet the requirements of Safety Class II.
- Instalimi i sistemeve fotovoltaike diellore kërkon aftësi dhe njohuri të specializuara. Duhet të kryhet vetëm nga personel i kualifikuar dhe i udhëzuar posaçërisht. Instaluesi merr përsipër të gjithë rrezikun e lëndimit, përfshirë rrezikun e goditjes elektrike.
- Përdorni vetëm pajisje, lidhëse, instalime elektrike dhe pajisje montimi të projektuara posaçërisht për përdorim në një sistem fotovoltaik.
- Before any manipulation at an installed PV plant, switch it off first on the AC-side, and then on the DC side of the inverter or the charge controller.
- Kur shkëputni telat e lidhur me një modul fotovoltaik që është i ekspozuar ndaj dritës, mund të ndodhë një hark elektrik. Harqet mund të shkaktojnë djegie, të ndezin zjarre ose të krijojnë probleme sigurie (deri në goditje elektrike vdekjeprurëse).
- Kontrollo për vëllimin e mbeturtage before starting and observe the local safety-relevant regulations for such working conditions.
- Në kushte normale, një modul fotovoltaik mund të prodhojë më shumë rrymë dhe/ose vëllimtage (këtu: 30V DC) sesa raportohet në kushtet standarde të provës.
- Kontaktoni me një voltage prej 30 V ose më shumë është potencialisht e rrezikshme. Tregoni kujdes kur lidhni instalime elektrike ose përdorni module të ekspozuara ndaj dritës së diellit.
- Lidhni vetëm modulet me të njëjtën rrymë dalëse nominale në seri. Nëse modulet janë të lidhura në seri, vëllimi i përgjithshëmtage është e barabartë me shumën e modulit individual voltages.
- Lidhni vetëm module ose kombinime seri modulesh me të njëjtin vëllimtage in parallel. If modules are connected in parallel, the total current is equal to the sum of the individual module or series combination currents.
- Gjithmonë përdorni të njëjtin lloj të modulit brenda një sistemi të veçantë fotovoltaik.
- If the sum of short circuit currents of the parallel-connected modules exceeds the reverse current, string diodes or fuses have to be used in each string of modules connected in parallel. These string diodes or fuses have to be qualified for the maximum expected current and voltage. The fuse rating value is also corresponds to the maximum reverse current that a module can withstand. The reverse current value can be found on the product label, in the product datasheet or in chapter 8 of the installation manual. Observe the instructions and safety precautions for all other components used in the system, including wiring and cables, connectors, DC-breakers, inverters, etc.
- Përdorni pajisje të përshtatshme sigurie (vegla të izoluara, doreza dielektrike, këpucë etj.) të miratuara për përdorim në instalimet elektrike.
KONFIGURIMI
- Në kushte normale, një modul fotovoltaik ka të ngjarë të përjetojë kushte që prodhojnë më shumë rrymë dhe/ose vëllimtage than reported at Standard Test Conditions (STC: 1000 W/ m2, AM 1.5, and 250C/770F cell temperature) or Bifacial nominal power index(BNPl front irradiance 1000 W/m2, back irradiance 135 W/m2 AM 1.5, and 25 OC/770F cell temperature). The short-circuit current (ISC) should be multiplied by a factor of 1.25 and the open-circuit voltage (VOC) duhet të shumëzohet me një faktor deri në 1.25 bazuar në temperaturën më të ulët dhe më të lartë të ambientit të regjistruar për vendin e instalimit kur përcaktohet vëllimi i komponentittagVlerësimet e, vlerësimet e rrymës së përcjellësit, madhësitë e siguresave dhe madhësia e kontrolleve të lidhura me daljen FV.
- VëlltagAto janë shtesë kur modulet FV lidhen drejtpërdrejt në seri dhe rrymat e modulit janë shtesë kur modulet FV lidhen drejtpërdrejt paralelisht. Modulet FV me karakteristika të ndryshme elektrike nuk duhet të lidhen direkt në seri. Përdorimi i pajisjeve elektronike të përshtatshme të palëve të treta të lidhura me modulet FV mund të mundësojë lidhje të ndryshme elektrike dhe duhet të instalohet sipas udhëzimeve të specifikuara të prodhuesit.
- Volumi maksimaltage of serial interconnection of the modules must be less than the maximum certified module’s system voltage. Gjithashtu, vëllimi maksimal i hyrjestagDuhet të merret parasysh e-ja e inverterit dhe e pajisjeve të tjera elektrike në sistem. Qarku i hapur vëlltage of the array string needs to be calculated at the lowest expected a mbient temperature forthe location. The maximal system voltage for the module is indicated in the module’s datasheet.
- Accordingly, for BLACKSTAR, SOLID or MAGNUS series modules, the values of ISC and VOC under STC or BNPI marked on this module should be multiplied by a factor of 1,25 when determining component voltage ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output. In the USA, referto Section 690-8 of the National Electrical Code (N EC) for an additional multiplying factor of 125 percent (80 percent de-rating) which may be applicable.
PAJISJET MBROJTJES NGA MBROJTJA (OCPD)
- When the potential reverse current of a PV string exceeds the rated SoliTek PV module series fuse rating (values indicated at the module datasheet) an overcurrent protection device (OCPD) must be used.
- An overcurrent protection device is required for each series string if more than two series are connected in parallel.
- In this case, it is needed to use one fuse per string rated at 1.25 x Isc or higher (Isc is the PV module’s short circuit current at STC). A PV fuse on each PV string will protect the PV modules and conductors from overcurrent faults and help minimize any safety hazards.
- The PV fuse will also isolate the faulted PV string so the balance of the PV system can continue to generate electricity.
- Siguresa amp vlerësimi ≥ 1.25 x Isc
- Zgjidhni vlerësimin tjetër standard më të lartë në katalogun e siguresave PV të disponueshme.
- Isc = Rryma e qarkut të shkurtër të një moduli në Kushtet Standarde të Testimit (STC).
- Duke marrë parasysh vlerat e Isc të moduleve SoliTek, vlera e duhur e siguresave PV që do të përdoren në instalim është 30 A. SoliTek rekomandon përdorimin e siguresave PV si në përçuesin pozitiv ashtu edhe në atë negativ.
KABLLO DHE INTERIMET
Modulet SoliTek PV pajisen me dy kabllo dalëse standarde, rezistente ndaj dritës së diellit, të cilat mbyllen me lidhës PV gati për shumicën e instalimeve. Terminali pozitiv (+) ka një lidhës mashkull, ndërsa terminali negativ (-) ka një lidhës femër. Lidhja e modulit është e destinuar për lidhjet serike (d.m.th., ndërlidhjet mashkullore (+) me femër (-)), por mund të përdoret gjithashtu për të lidhur pajisje elektrike të përshtatshme të palëve të treta që mund të kenë konfigurime alternative të instalimeve elektrike për sa kohë që ndiqen udhëzimet e prodhuesit.
Përdorni instalime elektrike në terren me zona të përshtatshme të prerjes tërthore që janë miratuar për përdorim në rrymën maksimale të qarkut të shkurtër të modulit PV. Të gjitha instalimet elektrike duhet të jenë kabllo të ndërlidhura me izolim të dyfishtë me një nivel minimal prej 1,8 kV (mbi 1500 V voltage) dhe një temperaturë minimale të vlerësuar prej 90 ˚C (190 °F). Madhësia e telit jo më pak se 4 mm² (12 AWG). Lloji i izolimit duhet të jetë i përshtatshëm për llojin e metodës së instalimit të përdorur dhe duhet të plotësojë kërkesat e IEC 61730 dhe të Klasës II të Sigurisë.
- Niveli i izolimit: 1,8 kV (përçues-përçues).
- Temperatura: -40°C deri në +90°C (-40°F deri në 190°F) të paktën.
- Konstruksioni i përcjellësit: tel bakri i kallajuar me fije bakri me pastërti bakri më të madhe se 99,9%.
- Izolimi kryesor: polietileni i ndërlidhur (XLPE), rezistent ndaj dritës së diellit dhe lagështisë, rezistent ndaj flakës. I përshtatshëm për kanale dhe pista të instaluara nën tokë.
- Izolimi (xhaketë): termoplastik, rezistent ndaj dritës së diellit, rezistent ndaj flakës, rezistent ndaj ujit.
- Diametri minimal i jashtëm i kabllit me izolim – 5,2 mm (2,05 inç).
- Seksioni kryq minimal i përcjellësit – 4 mm² (12 AWG).
SoliTek rekomandon instaluesit të përdorin vetëm kabllo rezistente ndaj dritës së diellit të kualifikuar për instalime elektrike me rrymë të drejtpërdrejtë (DC) në sistemet FV. Kabllot duhet të fiksohen në strukturën e montimit në mënyrë të tillë që të shmanget dëmtimi mekanik i kabllit dhe/ose modulit. Mos ushtroni stres në kabllo. Për fiksim, përdorni mjete të përshtatshme, të tilla si lidhëse kabllosh rezistente ndaj dritës së diellit dhe/ose kapëse për menaxhimin e telit. Ndërsa kabllot janë rezistente ndaj rrezeve të diellit dhe të papërshkueshëm nga uji, kur është e mundur, shmangni ekspozimin e drejtpërdrejtë të dritës së diellit dhe zhytjen në ujë të kabllove.
Gjatësia standarde e kabllove nga kutitë e kryqëzimit është 1,2 m (47,24 inç). Synohet që dy panele të ndërlidhen në sistem.
argumentim
- Module grounding must be done in accordance with the electrical design and construction specifications, procedures, regulations and other special grounding requirements applicable to the installation sites. If grounding is needed, it should be done accordingly:
Framed type modules grounding
Vrimat e shënuara me një shenjë tokëzimi në kornizë mund të përdoren vetëm për tokëzim. Mos shponi vrima shtesë të tokëzimit në kornizën e modulit.
The grounding conductor or strap may be copper, copper alloy, or any other material acceptable foruse as an electrical conductor in accordance with local electric codes and regulations.
Përçuesi i tokëzimit duhet më pas të bëjë një lidhje me tokëzimin duke përdorur një elektrodë tokëzuese të përshtatshme.
A bolted connection is required; it incorporates:
- Madhësia e bulonit M4.
- Një rondele dhëmbësh nën kokën e bulonit ose një bulon i dhëmbëzuar duhet të depërtojë në veshjet jopërçuese si korniza e anodizuar.
- Një arrë lidhëse e përshtatshme për bulonën M4.
- I gjithë hardueri duhet të jetë prej metali me ngjyra, çeliku inoks i serisë 300, ose i mbrojtur në mënyrë të përshtatshme nga korrozioni.
- Çift rrotullimi i rekomanduar i kyçjes së dados është 2 Nm÷2.2 Nm (1,48÷1,62 ft-lb).
- Bulon i tokëzimit duhet të kalojë nëpër të gjithë elementët lidhës.

- Pajisjet e listuara dhe të identifikuara për tokëzimin e kornizave metalike të moduleve FV lejohen të tokëzojnë kornizat metalike të ekspozuara të modulit në strukturat e montimit të tokëzuara.
- In any case the grounding screws or other parts have to be used separately from the mounting parts of the module.
- Alternate grounding options built through the mounting system are acceptable as long as they have been IEC and UL approved.
- Grounding resistance of the grounding structure shall be reached according to local regulations, Eurocodes, or other legal normative references.
Frameless type modules grounding
- Due to that modules are without frame, grounding is not forseen. Other PV plant equipment should be grounded according to the local and national electrical codes.
LIDHJET
- Connectors for SoliTek PV panels are Stäubli MC4-Evo 2. Keep connectors dry and clean and ensure that connector caps are hand-tight before connecting the modules.
- Mos u përpiqni të bëni një lidhje elektrike me lidhës të lagësht, të ndotur ose të dëmtuar.
- Shmangni ekspozimin ndaj dritës së diellit dhe zhytjen në ujë të lidhësve. Shmangni lidhësit që mbështeten në sipërfaqen e tokës ose të çatisë.
- Do not disconnect under load. Faulty connections can result in arcs and electrical shock.
- Kontrolloni që të gjitha lidhjet elektrike të jenë të lidhura mirë. Sigurohuni që të gjithë lidhësit e kyçjes të jenë plotësisht të kyçur dhe të kyçur.
DIODAT BYPASS
The PV module’s junction box contains 3 bypass diodes (one in each part of split junction box; Schottky type) connected in parallel with the PV cell strings. In the case of partial shading (hot-spot effect), the diodes bypass the current generated by the non-shaded cells, therebylimiting module heating and performance losses.
Diodat bypass nuk janë pajisje mbrojtëse nga mbirryma. Diodat e anashkalimit e devijojnë rrymën nga vargjet e qelizave në rast të hijes së pjesshme. Karakteristikat e këtyre diodave:
- VëlltagVlerësimi e – 50 V.
- Vlerësimi aktual - 25 A.
VLERËSIMI I KLASËS SË ZJARRIT
- Modulet SoliTek SOLID Bifacial dhe Blackstar janë miratuar nga testi i zjarrit IEC dhe kanë arritur Klasën e ndezshmërisë A. Testi i zjarrit është kryer në pjerrësinë 127 mm (5 inç) për 300 mm (11,81 inç), siç përshkruhet në pikën A.2.5 të IEC 61730-2.
- SoliTek SOLID Bifacial has fire rating of 28 according to UL1703-2 standard. SoliTek Blackstar has fire rating of 29 according to UL1703-2 standard.
Montimi mekanik
- The mechanical loads described in this manual are the test loads.
- For calculating the equivalent maximum design loads, a safety factor of 1.5 (Design load×1.5 safety factor=Mechanical test load) needs to be considered in compliance with the requirements of the local laws and regulations.
KËRKESAT E PËRGJITHSHME
- Modules can be mounted in landscape or portrait orientation. For the bifacial modules, in order to get notable bifacial gain, the distance between the bottom of the modules and the roof or ground surface shall be at least 0,8 m (31,50 inch).
- Also, the bifacial gain increases significantly if modules are installed above white, light-reflecting surfaces (under surfaces with high albedo value).
- If the mounting rails are installed across the module, the bifaciality effect will be lower due to back-side cells shading.
- Ju lutemi respektoni rregullat e sigurisë dhe udhëzimet e instalimit të përfshira me sistemin e montimit. Nëse është e nevojshme, ju lutemi kontaktoni direkt furnizuesin për informacione të mëtejshme.
- The modules must be safely set onto the mounting rail.
- The whole rail supporting the photovoltaic system must be strong enough to resist potential mechanical pressures caused either by wind or snow, in accordance with local, regional and state safety (and other associated) standards.
- The mounting system shall be tested and inspected by a third-party testing institution with static mechanical analysis capacity in accordance with local national standards or international standards.
- Before installing modules on a roof, ensure that the roof construction is suitable.
- In addition, any roof penetration required to mount the modules must be properly sealed to prevent leaks.
- Sigurohuni që hekurudha e montimit të mos deformojë ose të ndikojë në modulet kur zgjerohet si rezultat i zgjerimit termik.
- The module can appear thermal expansion and cold contraction; thus, the interval between two adjoining modules shall be no lesser than 10 mm (0,39 inch).
- Mos u përpiqni të hapni vrima në sipërfaqen e xhamit dhe kornizat e moduleve pasi kjo do të anulojë garancinë.
- The mounting method must not result in the direct contact of dissimilar metals with the aluminum frame of the modules that will result in galvanic corrosion.
Komponentët e montimit duhet të jenë prej materialesh të qëndrueshme, anti-korrozive dhe rezistente ndaj UV-së (rekomandohen komponentë prej çeliku inox dhe alumini të anodizuar).
MONTIMI ME CLAMPS
- Përdorni të paktën 4 kl. laminatamps për të rregulluar modulet në shinat e montimit. Modulet klampPjesët metalike nuk duhet të vijnë në kontakt me xhamin e përparmë ose të pasmë. Kur zgjidhni këtë lloj klamp-Mënyra e montimit, përdorni të paktën katër clamps në çdo modul; dy clamps duhet të ngjiten në secilën anë të gjatë. Në varësi të ngarkesës lokale të erës dhe borës, klampMund të kërkohen s për të siguruar që modulet mund të përballojnë ngarkesën.
- ClampÇift rrotullimi i shtrëngimit duhet të jetë së paku 15 Nm (11,06 ft-lb), por jo më i madh se 20 Nm (14,75 ft-lb). Zakonisht, 15 Nm (11,06 ft-lb), arrihet kur dy pro aluminifiles prekin njëri-tjetrin. Kur një modul instalohet në orientim portret në çatinë e pjerrët e cila ka pjerrësi >45°, kërkohet një goditje shtesë në fund të modulit.

SOLID Black, Semi-clear, Satin, Agro Frameless
Me shina tërthore


BLACKSTAR, SOLID Black 35(40) mm, SOLID Semi-clear 35(40) mm, SOLID Satin 35(40) mm, SOLID Agro 35(40) mm, Magnus Framed mounting
- Kur zgjidhni këtë lloj klamp-Mënyra e montimit, përdorni të paktën katër clamps në çdo modul; dy clamps duhet të ngjiten në secilën anë të modulit. Modulet klamps nuk duhet të bien në kontakt me xhamin e përparmë dhe nuk duhet të deformojnë kornizën.
- Sigurohuni që të shmangni efektet e hijes në qelizat diellore nga moduli clamps.
- The module frame is not to be modified under any circumstances. Do not to block the drain hole of the frame.
- Gjatësia e klamp should be at least 30 mm (1,18 inch).
- Klamp duhet të mbivendoset kornizën e modulit me të paktën 5 mm (0,2 inç), por jo më shumë se 10 mm (0,4 inç).
Me shina tërthore

Pa binarët tërthor ose binarët janë pingul me kornizën e gjatë anësore

Me sistem futjeje

Montimi me bulona
- Moduli duhet të jetë i lidhur dhe i mbështetur nga katër bulona çeliku inox M8 përmes vrimave të montimit të treguara në shufrat tërthor. Çift rrotullues në klamp bolt has to be in range of 8÷10 Nm (5,9÷7,38 ft-lb). The transversal bars positioning is shown in Figure 3.
- If additional mounting points are required, depending on the local wind and snow loads, then a mounting solution with clampduhet të zgjidhet hardueri.

- Mounting with bolts can be done only through dedicated predrilled holes in the frame.
- Shpimi i vrimave të reja është i ndaluar dhe do të anulojë garancinë.

POZICIONI I KUTIVE KRYESORE
- Për distancën midis kutisë së kryqëzimit dhe skajit të modulit ose dimensioneve të tjera të pozicionit dhe zonave të kutisë së kryqëzimit, ju lutemi referojuni figurave të paraqitura më poshtë.

MIRËMBAJTJA
- Për të siguruar performancën optimale të modulit, Solitek rekomandon sa vijon:
- Nëse është e nevojshme, pjesa e përparme e xhamit të modulit mund të pastrohet me ujë dhe një sfungjer ose leckë të butë.
- Një detergjent i butë, jo gërryes mund të përdoret për të hequr njollat më të forta.
- Kontrolloni periodikisht lidhjet elektrike dhe mekanike dhe sigurohuni që ato të jenë të pastra, të sigurta, të plota dhe të sigurta.
- Në rast problemi, konsultohuni me një person të licencuar/kualifikuar.
SPECIFIKIMET
| Parametri \ Model | BLACKSTAR B.96 | SOLID Black (Semi-Clear) B.96 35(40) mm | BLACKSTAR Satin B.96 | MAGNUS B.108 |
| Kushtet e testimit | STC | STC | STC | STC |
| Fuqia nominale | 455 W | 455 W | 445 W | 510 W |
| Të dhënat elektrike @STC | ||||
| Fuqia maksimale (Pmax), W | 455 | 455 | 445 | 510 |
| Vëlltage në fuqinë maksimale (Vmpp), V | 29,71 | 29,71 | 29,40 | 33,34 |
| Rryma në fuqinë maksimale (Impp), A | 15,31 | 15,31 | 15,14 | 15,30 |
| Qarku i hapur Voltage (Voc), V | 34,82 | 34,82 | 34,40 | 39,06 |
| Rryma e qarkut të shkurtër (Isc), A | 15,97 | 15,97 | 15,79 | 15,95 |
| Të dhënat termike | ||||
| Gama e temperaturës së funksionimit | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Koeficienti i temperaturës Pmax | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,362%/°C (°F) |
| Koeficienti i temperaturës së Voc | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,265%/°C (°F) |
| Koeficienti i temperaturës Isc | +0,036% /° C (°F) | +0,036% /° C (°F) | +0,036% /° C (°F) | +0,036% /° C (°F) |
| Të dhënat e madhësisë dhe peshës | ||||
| Gjatësia | 1762 mm | 1762 mm | 1762 mm | 1961 mm |
| Gjerësia | 1134 mm | 1134 mm | 1134 mm | 1134 mm |
| Trashësia | 30 mm | 35(40) mm | 30 mm | 30 mm |
| Pesha | 25,5 kg | 35 (36) kg | 25,5 kg | 28,5 kg |
| Metoda e montimit | ||||
| Reference to the chapter | 3.3 | 3.3 | 3.3 | 3.3 |
| Të tjera | ||||
| Rryma maksimale e kundërt, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/Lloji II | |||
| Vëllimi maksimal i sistemittage, V | 1500 | |||
Table 9. Electrical and mechanical parameters table.
| Parametri \ Model | I ngurtë Semi- clear B.96 | SOLID Black B.96 | I ngurtë Satin B.96 | I ngurtë Agro B.64 |
| Kushtet e testimit | STC | STC | STC | STC |
| Fuqia nominale | 455 W | 455 W | 445 W | 300 W |
| Të dhënat elektrike @STC | ||||
| Fuqia maksimale (Pmax), W | 455 | 455 | 445 | 300 |
| Vëlltage në fuqinë maksimale (Vmpp), V | 29,71 | 29,71 | 29,40 | 19,60 |
| Rryma në fuqinë maksimale (Impp), A | 15,31 | 15,31 | 15,14 | 15,31 |
| Qarku i hapur Voltage (Voc), V | 34,82 | 34,82 | 34,40 | 22,76 |
| Rryma e qarkut të shkurtër (Isc), A | 15,97 | 15,97 | 15,79 | 15,97 |
| Të dhënat termike | ||||
| Gama e temperaturës së funksionimit | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Koeficienti i temperaturës Pmax | -0,30%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) |
| Koeficienti i temperaturës së Voc | -0,25%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) |
| Koeficienti i temperaturës Isc | +0,045% /° C (°F) | +0,045% /° C (°F) | +0,045% /° C (°F) | +0,045% /° C (°F) |
| Të dhënat e madhësisë dhe peshës | ||||
| Gjatësia | 1772 2 mm | 1772 2 mm | 1772 2 mm | 1772 2 mm |
| Gjerësia | 1144±2 | 1144±2 | 1144 2 mm | 1144 2 mm |
| Trashësia | 7,2 mm | 7,2 mm | 7,2 mm | 7,2 mm |
| Pesha | 33 kg | 33 kg | 33 kg | 33 kg |
| Metoda e montimit | ||||
| Reference to the chapter | 3.2 | 3.2 | 3.2 | 3.2 |
| Të tjera | ||||
| Rryma maksimale e kundërt, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/Lloji II | |||
| Vëllimi maksimal i sistemittage, V | 1500 | |||
Table 10. Electrical and mechanical parameters table.
| Parametri \ Model | SOLID Satin B.96 35 mm | SOLID Satin B. 96 40 mm | SOLID AgroB.64 35 mm | SOLID AgroB.64 40 mm |
| Kushtet e testimit | STC | STC | STC | STC |
| Fuqia nominale | 445 W | 445 W | 300 W | 300 W |
| Të dhënat elektrike @STC | ||||
| Fuqia maksimale (Pmax), W | 445 | 445 | 300 | 300 |
| Vëlltage në fuqinë maksimale (Vmpp), V | 29,40 | 29,40 | 19,60 | 19,60 |
| Rryma në fuqinë maksimale (Impp), A | 15,14 | 15,14 | 15,31 | 15,31 |
| Qarku i hapur Voltage (Voc), V | 34,40 | 34,40 | 22,78 | 22,78 |
| Rryma e qarkut të shkurtër (Isc), A | 15,79 | 15,79 | 15,97 | 15,97 |
| Të dhënat termike | ||||
| Gama e temperaturës së funksionimit | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Koeficienti i temperaturës Pmax | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) |
| Koeficienti i temperaturës së Voc | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) |
| Koeficienti i temperaturës Isc | +0,036% /° C (°F) | +0,036% /° C (°F) | +0,045% /° C (°F) | +0,045% /° C (°F) |
| Të dhënat e madhësisë dhe peshës | ||||
| Gjatësia | 1762 mm | 1762 mm | 1762 mm | 1762 mm |
| Gjerësia | 1134 mm | 1134 mm | 1134 mm | 1134 mm |
| Trashësia | 35 mm | 40 mm | 35 mm | 40 mm |
| Pesha | 35 kg | 36 kg | 35 kg | 36 kg |
| Metoda e montimit | ||||
| Reference to the chapter | 3.3 | |||
| Të tjera | ||||
| Rryma maksimale e kundërt, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/Lloji II | |||
| Vëllimi maksimal i sistemittage, V | 1500 | |||
Table 11.Electrical and mechanical parameters table.
- The electrical characteristics are within of the indicated values of ISC (φISC) ±3%, VOC (ϕVOC) ±3,5% and PMPP (ϕPmax) ±5%, under Standard Test Conditions (STC) (irradiance of 1000 W/m²,AM 1.5 spectrum, and a cell temperature of 25°C / 77°F)
- Të gjitha panelet SoliTek SOLID PV korrespondojnë me klasën II të sigurisë elektrike.
Mohimi i përgjegjësisë
- Duke qenë se është e pamundur që SoliTek të kontrollojë instalimin, funksionimin, aplikimin dhe mirëmbajtjen e sistemit fotovoltaik sipas këtij udhëzimi. SoliTek nuk pranon përgjegjësi dhe shprehimisht mohon përgjegjësinë për çdo humbje, dëmtim ose shpenzim që lind nga ose në ndonjë mënyrë të lidhur me këtë instalim, funksionim, përdorim ose mirëmbajtje.
- SoliTek will not take any responsibility for any possible violation of patent rights and third-party rights that are related to the application of the solar energy system. No permission of patents is given through implication.
- The information of this instruction is from the knowledge and experiences of SoliTek. However, the instructions and suggestions of this instruction do not make an external or internal of guarantee. SoliTek reserves the right to revise this instruction, products and all the information about products without prior notification to customers.
FAQ
- Q: What should I do before installing the PV modules?
- A: Read this entire guide, understand all instructions, and ensure compliance with all local, state, and federal regulations. Consult a certified building specialist for the structural integrity of the dwelling.
- Q: Can I install the PV modules myself without professional training?
- A: This documentation is not a complete installation manual for personnel not specifically trained in PV-modules. It serves as a general but strictly mandatory reference for the installer. Professional installation is highly recommended.
- Q: What happens if I don’t follow the instructions in this guide?
- A: Failure to follow instructions may damage system components, endanger personnel, damage property, or invalidate the panel warranty.
- Q: Is it safe to work on a rooftop during installation?
- A: Do not attempt to work on a rooftop until safety precautions have been identified and taken, including fall protection measures, ladders or stairways, and personal protective equipment (PPE). Avoid adverse conditions like strong winds or wet/frosted roofs.
- Q: How should I store the PV modules before installation?
- A: Store pallets in a cool and dry location until the PV modules are ready to be unpackaged. Do not exceed the maximum stacking height indicated on the packaging.
Dokumentet / Burimet
![]() | SOLID Series Solar Modules |
Referencat
- Solitek.euwww.solitek.eu
- Manuali i Përdoruesitmanual.tools

